ISO 50002 or DIN EN 16247-1: which standard counts for your energy audit
ISO 50002-1:2025 is the international energy audit standard; the German EDL-G requires DIN EN 16247-1. What each one covers and which applies to your audit.
As of: 24 November 2026 · Sources: Energy Services Act (EDL-G), sections 8, 8a and 8b, current version; BAFA, Merkblatt für Energieaudits, as of 16 Sep 2026; DIN Media, catalogue entries ISO 50002-1:2025-06 and ISO 50002:2014-07, as of 17 Nov 2026; ISO and EVS, catalogue entries, and ISO 50002-1:2025, table of contents, foreword and introduction, as of 20 Nov 2026; BAFA, Referat 512, written answer on request, 24 Nov 2026
In short
For the energy audit under the German Energy Services Act (EDL-G), the standard that counts in Germany is DIN EN 16247-1, November 2022 edition. ISO 50002-1 is the international standard for energy audits; its June 2025 edition replaces ISO 50002 of 2014. The EDL-G does not mention ISO 50002. You need ISO 50002 only if your group, your customer or your certifier asks for it. Both standards describe how an energy audit is run; where they differ is shown in the table below.
What ISO 50002 is
ISO 50002, since June 2025 published as ISO 50002-1:2025, “Energy audits – Part 1: General requirements with guidance for use”, is the standard of the International Organization for Standardization (ISO) for energy audits. It describes how an energy audit is planned, carried out and reported: from the agreement with the company through data collection and the site visit to the report with the saving opportunities. It applies to any organization, regardless of size, location, sector or the type of energy used; for buildings and processes it refers to separate parts with guidance.
The first edition appeared in July 2014 in English, with 22 pages. Since June 2025 the current edition is ISO 50002-1:2025, 37 pages, also in English (DIN Media, catalogue entries, as of 17 Nov 2026). On 17 November 2026 DIN Media offered no German version.
What applies in Germany
The EDL-G requires an energy audit to comply with DIN EN 16247-1, November 2022 edition (section 8a (1) no. 1 EDL-G). ISO 50002 does not appear in the Act. A company that is obliged to audit must therefore meet the requirements of the European standard; the international one alone is not enough. Only a person registered with the Federal Office for Economic Affairs and Export Control (BAFA) may carry it out (section 8b EDL-G).
Neither the Act nor the BAFA guidance sheet names ISO 50002; they require the audit to meet the requirements of DIN EN 16247-1 and section 8a EDL-G. In reply to our enquiry, the BAFA (Referat 512) wrote on 24 November 2026: an energy audit prepared under ISO 50002 that meets the requirements of section 8a EDL-G is “durchaus anerkennbar” (can certainly be recognised) in its review, provided it is confirmed that all these requirements are met. The report should therefore confirm this explicitly, point by point against DIN EN 16247-1 and the BAFA guide.
Who is obliged to carry out an energy audit is explained in the article Energy audit obligation under the EDL-G.
What is new in 2025
ISO 50002-1:2025 replaces ISO 50002:2014. One standard becomes a series, all three parts published in June 2025: Part 1 with the general requirements, Part 2 with guidance for buildings and Part 3 with guidance for processes.
For a company in Germany the new edition changes nothing about the obligation: the EDL-G still names DIN EN 16247-1.
ISO 50002-1 and DIN EN 16247-1 compared
ISO 50002 of 2014 was built on the European EN 16247-1. Until DIN EN 16247-1 was revised in November 2022, both standards had the same structure; the differences lay in individual requirements (see WEKA, “Unterschiede bei Energieaudits nach ISO 50002 und DIN EN 16247-1”, as of 11 Jan 2023). The table below compares the current editions; where only the 2014 edition of the ISO standard is documented, the cell says so.
Feature
ISO 50002-1:2025
DIN EN 16247-1:2022
Legal basis in Germany
None. The EDL-G does not mention ISO 50002
Mandatory standard for the energy audit under section 8a (1) no. 1 EDL-G
Current edition
June 2025; replaces ISO 50002:2014
November 2022
Language
English, 37 pages; no German version at DIN Media (as of 17 Nov 2026)
German
Structure
Three parts: general requirements (Part 1), guidance for buildings (Part 2) and for processes (Part 3)
EN 16247 series: general requirements (Part 1), buildings (Part 2), processes (Part 3), transport (Part 4), competence of energy auditors (Part 5)
Roles and contact person before the audit
Roles and responsibilities of the organization and the auditor are set (according to WEKA for 2014: before planning starts); plus guidance on the auditor’s competence
Initial contact and kick-off meeting; the EDL-G also requires the company to name a responsible person (section 8a (1) no. 1)
Measurement plan
Part of the standard, clause 5.5 (also 5.5 in the 2014 edition, according to WEKA)
Since 2022 clause 5.4, as an agreement between auditor and organisation
Sampling procedure
Since 2025 as guidance in the informative Annex C “Sampling”; the 2014 edition had none, according to WEKA
Included since 2022
Data analysis and report
Analysis in clause 5.7 (current energy performance; identifying, evaluating and prioritizing improvements), report in 5.8; according to WEKA, the 2014 edition was more detailed here than the EN (assumptions behind measurements and estimates, summary of energy input and consumption)
Report as per the standard; in Germany additionally the BAFA’s requirements (Merkblatt für Energieaudits)
Relation to ISO 50001
An audit to it can be part of the ISO 50001 energy review; Annex B.1 gives guidance on this
A certified ISO 50001 system exempts from the audit (section 8 (3) EDL-G; BAFA, Merkblatt, 2.4)
Which standard applies to you?
We distinguish four cases. Yours may be made up of several.
1. Your company is obliged under the EDL-G to carry out an energy audit. For you DIN EN 16247-1, November 2022 edition, counts, carried out by a person registered with the BAFA. Ask for exactly this standard and this registration in the offer. An offer that only says “to ISO 50002” does not name the standard of the Act; ask about it.
2. Your company has a certified energy management system under ISO 50001. Then the system exempts you from the compulsory audit (section 8 (3) EDL-G) if it covers at least 90 % of your total final energy consumption (BAFA, Merkblatt fĂĽr Energieaudits, 2.4). An audit to ISO 50002-1 can be part of the energy review that ISO 50001 requires; it is not prescribed. Ask your certifier what they expect for it.
3. Your company belongs to an international group. Head office knows the ISO and may ask for an audit “to ISO 50002” at every site. Before the BAFA, such an audit counts if it meets every requirement of section 8a EDL-G, including those of DIN EN 16247-1, and the report confirms it (written answer from the BAFA of 24 November 2026). One report can do both: follow the German standard and name the points of ISO 50002-1. Whether your head office accepts such a report, clarify with them beforehand.
4. None of the three cases applies. Then the audit is voluntary for you. Choose the standard by its purpose. For savings and a grant application in Germany, DIN EN 16247-1 is the suitable basis. The BAFA grant is explained in the article The BAFA and your energy audit.
Not sure which case applies to you? In an initial call we clarify with you which standard your audit needs and what your offer should name.
How our energy audit to DIN EN 16247-1 works is described on the Energy audit page.
DIN EN 16247-1 – the standard the EDL-G requires for the energy audit.
EDL-G – who is obliged to carry out an energy audit, from when and how often.
ISO 50001 – the energy management system that exempts from the audit.
DIN EN 17463 (VALERI) – the valuation of the measures after the audit.
What this article does not cover
This article explains two standards and says which one applies in Germany. It does not replace the text of the standards, which are available from DIN Media and from ISO. It does not deal with the certification of persons as energy auditors, nor with the audit of a management system under ISO 50001. Who is obliged to carry out an energy audit is explained in the article Energy audit obligation under the EDL-G. This article is not legal advice.
Frequently asked questions
Does ISO 50002 apply to my energy audit in Germany, or DIN EN 16247-1?
For the compulsory audit under the EDL-G, DIN EN 16247-1, November 2022 edition, applies in Germany (section 8a (1) no. 1 EDL-G). The Act does not mention ISO 50002; it counts only if your group, customer or certifier asks for it.
What are the differences between ISO 50002 and DIN EN 16247-1?
Until DIN EN 16247-1 was revised in November 2022, ISO 50002 (2014 edition) and the EN had the same structure. The differences lay in four points: roles, the contact person and the auditor’s competence are fixed in the ISO before planning; since 2022 the EN contains a measurement plan (clause 5.4) and a sampling procedure, while ISO 50002 of 2014 has the measurement plan (clause 5.5) but no sampling procedure; the ISO describes data analysis and the report in more detail (WEKA, as of 11 Jan 2023). In the 2025 edition of the ISO, the measurement plan is in clause 5.5 and a sampling procedure is given as guidance in the informative Annex C; it sets the roles of the organization and the auditor and gives guidance on the auditor’s competence. In Germany the EDL-G requires DIN EN 16247-1.
What is new in ISO 50002-1:2025?
ISO 50002-1:2025 appeared in June 2025 and replaces ISO 50002 of 2014 (DIN Media, read on 17 Nov 2026). One standard becomes a series: Part 1 with the general requirements, Parts 2 and 3 with guidance for buildings and for processes. According to the standard’s foreword, the main changes are: terms aligned with ISO 50001:2018, new principles, decarbonization (renewable energy, net zero) as part of the improvement opportunities, and clarified energy auditor competencies.
Is an energy audit to ISO 50002 enough for the energy audit obligation?
The EDL-G requires DIN EN 16247-1 for the compulsory audit. A report that only names ISO 50002 does not name the standard of the Act. An audit to ISO 50002-1 counts before the BAFA if it meets every requirement of section 8a EDL-G, including those of DIN EN 16247-1, and the report confirms it: the BAFA (Referat 512) told us so in writing on 24 November 2026, in reply to our enquiry.
Do I need ISO 50002 for ISO 50001?
ISO 50001 requires an energy review; which standard you use for it, it does not prescribe. An audit to ISO 50002-1 can be part of it; its Annex B.1 gives guidance on this. Your certifier will tell you what they expect.
Is ISO 50002 available in German?
On 17 November 2026 DIN Media offered only the English version of ISO 50002-1:2025. DIN EN 16247-1 is available in German.
What is the difference between ISO 50002 and ISO 50001?
ISO 50002 describes a single energy audit: an investigation with a report. ISO 50001 describes an energy management system: a permanent process in the company that can be certified. The audit is a building block of the system, not the system.
Who may carry out an energy audit to ISO 50002?
ISO 50002-1:2025 gives guidance on the energy auditor’s competence in clause 6: general and energy-specific knowledge, and that of a lead auditor. For the compulsory audit under the EDL-G, only a person registered with the BAFA may audit in Germany (section 8b EDL-G).
Sources
Energy Services Act (Energiedienstleistungsgesetz, EDL-G) – section 8 (3), section 8a (1), section 8b, current version, last amended by Art. 3 of the Act of 27 Feb 2025. · Download copy (PDF, as of 25 Oct 2026, German)
BAFA: Merkblatt für Energieaudits (guidance on energy audits), as of 16 Sep 2026 – section 2.4 (exemption by a management system, 90 %) and p. 20 (requirements of DIN EN 16247-1). · Download copy (PDF, German)
BAFA: Merkblatt FAQ (FAQ on sections 8 ff. EDL-G and sections 8 to 10 EnEfG), as of 1 Sep 2026 – 2.3.5 and 2.4.5. · Download copy (PDF, German)
BAFA: Leitfaden zur Erstellung von Energieauditberichten (guide to writing energy audit reports), as of 1 Sep 2026 – p. 10 (items 5.1 “Einleitender Kontakt” and 5.2 “Auftakt Besprechung”). · Download copy (PDF, German)
BAFA, Referat 512 (energy efficiency register, energy audits): written answer to EM-OUT by e-mail of 24 Nov 2026, to our enquiry of 21 Nov 2026 (not published).
DIN Media: catalogue entry ISO 50002-1:2025-06, “Energy audits – Part 1: General requirements with guidance for use”, issued 2025-06, original language English, 37 pages, “replaces ISO 50002:2014-07”.
DIN Media: catalogue entry ISO 50002:2014-07, “Energy audits – Requirements with guidance for use”, issued 2014-07, original language English, 22 pages, withdrawn, “replaced by ISO 50002-1:2025-06”.
ISO: catalogue entries ISO 50002-1:2025 (no. 83645, 37 pages), ISO 50002-2:2025 “Guidance for conducting an energy audit using ISO 50002-1 in buildings” (no. 83662, 21 pages) and ISO 50002-3:2025, the same guidance for processes (no. 83663, 19 pages), all published 2025-06, as of 20 Nov 2026.
EVS (Estonian Centre for Standardisation and Accreditation): catalogue entries ISO 50002-1:2025, with section 1 “Scope”, and EN 16247-1 to EN 16247-5, as of 20 Nov 2026.
ISO 50002-1:2025: table of contents (DIN Media) and the foreword and introduction (0.3) from the sample of the published edition.
ISO 50001:2018: table of contents (6.3 “Energy review”) and section 2 “Normative references”, from the sample.
WEKA Media: “Unterschiede bei Energieaudits nach ISO 50002 und DIN EN 16247-1” (differences between energy audits to ISO 50002 and DIN EN 16247-1), last updated 11 Jan 2023 – on the differences between ISO 50002 of 2014 and DIN EN 16247-1 of 2022.
Co-founder and Chief Technology Officer, EM-OUT. Tito Morales is an industrial engineer (Ingeniero Industrial, Pontificia Universidad Javeriana, Colombia), co-founder of EM-OUT in Stuttgart and its Chief Technology Officer since 2014. He develops the analysis tools EM-OUT uses to evaluate load profiles and consumption. He works on building energy simulations for LEED to ASHRAE 90.1 and on energy audits to DIN EN 16247-1. He writes the expert articles on em-out.de.
What you must report to the BAFA after an energy audit, what it asks for in a spot check, how to tell a registered energy auditor, and who gets the funding.